D-300 | D-300-3V | |
---|---|---|
Sensing Method | NDIR (Non-dispersive Infrared) / Dual Type | |
Dimensions | 33mm×33mm×13.1mm (10g) | |
CO₂ Measurement range | 0 ~ 2,000 (3,000/5,000/10,000ppm, 2%/3%/5% models are available) | |
Accuracy | ± 30ppm ± 3% of reading (±300ppm ±3% of reading - 2%/3%/5% models) | |
Operating Temperature range | -20 ~ 50℃ | |
Storage Temperature | -30℃ to 70℃ | |
Operating Humidity range | 0 to 95% RH (Non-condensing) | |
Input Power | 5.0V±5% | 3.2V ~ 3.6V |
Power consumption | Normal:25㎃ / Max. 250㎃ / Sleep. 0.5㎃ | Normal : 12㎃ / Max : 180㎃ / Sleep : 0.3㎃ |
Response Time (90%) | 150 Sec / 90 Sec | |
Sampling Interval | 3 Sec | |
Output | UART- 38,400BPS, 8bit, No parity, 1 stop bit TTL Level I2C => Slave PWM (Option) |
|
Analog Voltage (Option) => VDC 0.5 to 4.5V (linear output) | Analog Voltage (Option) => VDC 0.5 to 3.0V (linear output) |
Products | Option List |
---|---|
D-300L(-3V) (LowPower) | Sleep mode is added on D-300 for Low power, which consume < 0.5mA |
D-300G(-3V) (99%Humidity) | Resistance up to 99% Humidity is added on D-300, for Application of Green House |
D-300LG(-3V) | Sleep mode + 99% Humidity |